vyges-em-ir

EM / IR-drop power-integrity sign-off: a power-grid resistor network in, a power-integrity report out.

Vyges open EDA tools. Commercial-grade silicon sign-off capability, built on open standards and plain file formats — and meant to be accessible to everyone, not only teams who can license a six-figure tool. vyges-em-ir opens up power-integrity sign-off.

Docs: docs.vyges.com — this engine's chapter, the cross-engine integration guide (how the four Vyges engines work together and where each plugs into an OpenROAD / LibreLane flow), and the job-file formats. Integrating at the binary level and need help?https://vyges.com/contact.

Why this exists

Logic only works if the power gets there. The power-distribution network (PDN) — the mesh of supply straps and vias — has resistance, so real current draw makes the on-chip supply sag below nominal (IR drop), which slows or breaks timing, and pushes current density in the wires toward the electromigration limit, which shortens the chip's life. Power sign-off proves both are within budget.

How this is solved today

In production, power sign-off is done with the commercial IR/EM sign-off tools — static and dynamic IR, EM rules, electrothermal — gated behind major licenses. The open baseline is PDNSim (in OpenROAD), which does static IR and basic EM. vyges-em-ir is an open engine in that space, behind a plain resistor-network file format, correlated against PDNSim as its baseline.

Describe the job, not the script. The incumbent power-sign-off flows are driven by hand-written Tcl — a recurring source of silent typos, copy-paste drift, and brittle maintenance. vyges-em-ir takes a small declarative job file (.emir) instead: readable, diffable, schema-checkable, with no control flow to get wrong. This is a toolchain-wide property — char, sta-si, and extract are configured the same way.

Validate fast, sign off with your tool. vyges-em-ir works from a plain resistor-network / DEF + power description, so it complements rather than replaces the golden flow: run fast IR/EM checks during iteration, and keep the commercial IR/EM sign-off tools for final power sign-off. It sits alongside what you already run (correlated to PDNSim as its baseline) — the quick inner-loop check where you most need fast feedback.

The problem it solves

Given a PDN resistor network — supply pads at a fixed voltage, resistive strap/via segments, and per-node current loads — it solves the conductance system for every node voltage, then reports:

  • the worst IR drop (supply sag vs nominal, in volts and % of vdd), and
  • every EM segment whose current |Δv|/R exceeds its per-layer limit.

The solve is Gauss-Seidel over the reduced free-node system (the PDN is diagonally dominant, so it converges).

When & how to use it in your flow

  layout (PDN) ──► PDN resistor network ──┐
  per-instance power ──► node currents ───┤
                                          ▼
                            ┌───────────────────────────┐
                            │        vyges-em-ir         │
                            └───────────────────────────┘
                                          │
                                          ▼
                   worst IR drop + EM violations ──► within budget? sign off :
                                                     widen straps / add pads / vias

Run it after place-and-route and PDN generation (you have the supply grid) and after a power estimate (so you know the per-node current draw), and before tape-out. What it gives you is the answer to "does my power grid hold up?" — the worst IR-drop node and the over-limit EM segments tell you exactly where to widen straps, add vias, or add pad connections. In the open RTL→GDS flow it occupies the slot where PDNSim runs.

Use it

# build it yourself (std-only, no deps) -- or grab a binary from GitHub Releases:
cargo build --release            # std-only, no external deps

vyges-em-ir run  block.emir -o block.rpt          # analyze -> report
vyges-em-ir run  block.emir --json                # machine-readable IR/EM
vyges-em-ir run  block.emir --fail-on-violation   # exit 3 if IR/EM over budget (CI gate)
vyges-em-ir check block.emir                       # validate the job + inputs
vyges-em-ir demo                                   # analyze a built-in PDN
# common flags: -o FILE · --json · -q/--quiet · -v/--verbose · -h/--help · -V/--version

A job (*.emir) points at a PDN and sets the IR budget:

design:       block
pdn:          block.pdn
ir_limit_pct: 5.0        # fail if worst IR drop exceeds 5% of vdd

A PDN (*.pdn) is a small resistor network:

vdd 1.8
pad p1                  # supply pad, tied to vdd
res p1 a 0.05 met5      # resistor: nodeA nodeB ohms [layer]
via a  m1 2.0           # a via resistance
load c 0.010            # current drawn out of a node (amps)
emlimit met5 0.50       # per-layer EM current limit (amps/segment)

A complete, runnable example is in examples/block/; vyges-em-ir run examples/block/block.emir reports IR drop + EM on a small mesh.

Domain coverage — digital and analog / mixed-signal

The solve is generic physics: G·V = I over a conductance matrix, where G is a resistor mesh and I is per-node current. Nothing in the path assumes standard cells, a clock, or digital switching activity — the .pdn is just supply pads, resistors/vias, and node loads. The current can come from any source: digital activity (a power estimate per instance) or an analog DC operating point (bias / power-amplifier branch currents). So vyges-em-ir runs on analog and mixed-signal supply grids exactly as it does on digital ones — same IR-drop and EM (current-density) check, same file format.

  • Digital: examples/block/ — a std-cell block's PDN mesh with a lumped load.
  • Analog: examples/analog_bias/ — an analog supply grid (pad → met5 strap → met4 mesh → via stack to met1) driven by two op-point currents: a 1 mA bias reference and a 30 mA power-amplifier branch at the most distant node. The worst IR drop lands on the PA branch (highest current × longest resistive path), and the via feeding it is the EM hotspot.
vyges-em-ir run examples/analog_bias/analog_bias.emir   # IR drop + EM on an analog grid

Scope here is physical power-integrity (IR drop, EM current density); analog functional / DC operating-point sign-off is out of scope — the op-point currents come from an external simulator (e.g. SPICE), and this engine consumes them, it doesn't solve the analog circuit.

Open core, certified fab plugins

vyges-em-ir is open and contains no foundry-confidential data. It runs out of the box on any PDN network you describe. What is fab-specific — the per-layer EM current-density limits and the electrothermal rules for a given node — is delivered as a separate, per-foundry plugin under that foundry's NDA, never in this repository.

  vyges-em-ir — OPEN engine  (Apache-2.0, contains no fab data)
  ────────────────────────────────────────────────────────────────────
    PDN network (pads · resistors · loads)  ─►  solve V  ─►  IR drop / EM
                                              ▲
                                              └─ published plugin contract
                                                 (per-layer EM limits · thermal rules)
                                       │
        ┌──────────────────────────────┴──────────────────────────────┐
  OPEN reference plugin                          CERTIFIED per-fab plugins
  (in-repo · no NDA)                             (private · one per fab/node 🔒)
    • generic EM limits in the .pdn                • vyges-em-ir-tsmc28
      ✓ runs out of the box                        • vyges-em-ir-sec28
                                                   EM density + electrothermal, under NDA

Current state (2026-05-30)

v0 did static (DC) IR drop via a Gauss-Seidel solve of the conductance system plus per-layer EM current-limit checks. It now also does dynamic (transient) IR drop: add node capacitance (cap) and switching-current events (switch) to the PDN and the engine runs a backward-Euler time-stepping solve (each step a conductance solve with C/dt on the diagonal), reporting the deepest droop reached at any node and when. The dynamic droop exceeds the static IR because the instantaneous current peaks beat the DC average — which is the point of the check.

The char → em-ir seam. A switch event's charge is energy / vdd, where energy is the per-switch supply energy vyges-char characterizes (its internal_power table value plus the net's load-charging ½·C·V²). So a flow runs char to get per-cell switching energy, annotates each switching instance, and em-ir turns those into the time-domain current pulses that drive the transient droop — the per-instance dynamic power flows straight from the characterizer into power-integrity. Demonstrated end-to-end on a small block using the measured sky130 inv_1 energy (~0.0151 pJ/switch): dynamic droop 0.07% vs static 0.05%, resolved to the switching instant. Fully offline, no external deps, 12 tests green.

Adds PDN extraction from DEF/LEF: a def (special-net power grid) + tech lef (per-layer RESISTANCE RPERSQ) build the resistor network instead of a hand-written .pdn. Each special-net wire segment becomes R = rpersq · L/W, nodes key on (layer, x, y), and the pad_layer nodes are tied to the supply. Via stacks are resolved: each wire is split at any via landing on it (so a via that lands mid-stripe gets a node), single-point via-only landings are kept as nodes, and at each via location the adjacent metal layers present are connected in stack order (met1-via-met2-via2-…) — so a met1 rail → via stack → met5 strap path is continuous.

Validated exactly on a synthetic stripe grid (hand-checked 1 Ω stripes, 1 mV droop, mid-segment via split) and on a real sky130 routed DEF + tech LEF (the m0 counter): extracts a 53-node grid and solves to a worst IR drop of 1.92 % on a met1 rail (the lowest layer, where cells draw current, reached up through the via stack to the met5 supply) — the physically expected hotspot.

The full char → em-ir seam on silicon. With a power_map (cell → per-switch energy, from vyges-char) the engine reads the DEF COMPONENTS placements, looks up each instance's cell energy, and lands its current on the nearest supply-rail node: a static average (energy/vdd)·f·activity and a switch event (same energy) for the transient solve. So per-instance dynamic power flows from the characterizer onto the real extracted grid. Demonstrated on the sky130 m0 counter (char-derived energies, 53 extracted nodes): static IR 0.11 % but a worst-case-simultaneous dynamic droop of 19 % on a met1 rail — the ~180× gap dynamic IR exists to catch.

Measured activity via current_map (the vyges-power seam). That static current uses a uniform activity — the worst case. A current_map: job key replaces it with per-instance current from vyges-power's activity map (instance avg_current_a …, from a VCD or vectorless estimate), so the IR/EM solve reflects measured activity instead of worst-case-simultaneous switching — each instance's current lands on its nearest node, char energy still drives its switch event. Closes char → power → em-ir. (Empty → the old q·f·activity behaviour.)

Decap extraction. A decap_map (decap cell → capacitance, pF) lands each placed decoupling cell's capacitance on its nearest supply-rail node, so the real on-chip decoupling participates in the transient solve (no uniform-cap guess). On the counter the 30 placed decap_3 cells lower the dynamic droop (19.0 % → 17.4 % at 10 fF each; the magnitude scales with the real per-cell value), leaving the DC IR unchanged — as decoupling capacitance should.

Real EM from the LEF — DC, RMS and peak. When the grid is extracted, each wire's EM limits are its LEF current-densities (mA/µm) × the wire's own width — per-segment, width-dependent, not a flat per-layer number. The DC-average (DCCURRENTDENSITY AVERAGE) limit is checked against the static segment current; the RMS and peak (ACCURRENTDENSITY RMS/PEAK) limits are checked against the segment's RMS and peak current taken from the transient solve. On the sky130 counter (real LEF limits: DC met1/2 2.8 · met3/4 6.8 · met5 10.17, RMS met1 6.1 mA/µm) a 20 mA static draw flags 1 / 39 segments over the DC limit; the seam run does 78 checks (DC + RMS per segment) from the transient.

The road to sign-off grade builds on the same network model: per-cut via EM, a faster solver (warm-started / CG / multigrid for large grids), and electrothermal coupling (the BCD/power axis — the engine reserves the EmIrError::ElectrothermalNotModeled hook).