before using it, the module has to be calibrated, which is easy. you'll need a (ideally precise) voltage source (like o_C) and a patch-cable.
- make sure no cables are plugged in and turn all the knobs to zero (fully CCW).
- push down the "learn" button while powering up the module. the LED next to the "learn" button should light up: the module is in calibration mode.
- once in calibration mode, again make sure nothing is plugged in and all the knobs are set fully CCW. push the "learn" button to initiate the procedure: the 5 LEDs next to the trigger/gate inputs will light up one by one ( = calibrating the offsets).
- next, we'll calibrate V/oct (using the voltage source) by feeding the module 1V, then 3V:
- 1V: push the "learn" button again — only the top-most LED will light up: feed the top-most pitch input (= channel #1) 1.000V.
- 3V: push the "learn" button again — the three top-most LED will light up: feed the top-most pitch input (= channel #1) 3.000V.
- (NB: if the V/oct calibration fails (it will fail if it thinks the calibration voltages are off), the "learn" LED will blink (indefinitely). you'll have to reboot and retry).
- push the "learn" button one more time to save + exit.
- power-cycle the module. done.