35 changes: 29 additions & 6 deletions apps/predbat/prediction.py
Original file line number Diff line number Diff line change
Expand Up @@ -816,23 +816,39 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi
over_limit = abs(diff) - export_limit
reduce_by = over_limit

if reduce_by > battery_draw:
# Compare the AC over-export against the battery's AC export contribution (battery_draw is DC,
# so that is battery_draw * inverter_loss). If the surplus is larger then even stopping the
# battery leaves PV over the limit, so we must charge to absorb it rather than clip the solar.
if reduce_by > battery_draw * inverter_loss:
if self.inverter_can_charge_during_export:
reduce_by = reduce_by - battery_draw
# Stopping the battery only removes its AC export contribution (battery_draw is DC, so
# that is battery_draw * inverter_loss). Whatever AC export is still over the limit has
# to be absorbed by charging the battery.
reduce_by = reduce_by - battery_draw * inverter_loss

if inverter_hybrid:
charge_rate_now_curve_dc = (
get_charge_rate_curve_cached(soc, battery_rate_max_charge_dc, soc_max, battery_rate_max_charge_dc, battery_charge_power_curve_tuple, battery_rate_min, battery_temperature, battery_temperature_charge_curve_tuple)
* battery_rate_max_scaling
)
charge_rate_now_curve_dc_step = charge_rate_now_curve_dc * step
battery_draw = max(-reduce_by * inverter_loss, -battery_to_min, -charge_rate_now_curve_dc_step)
# Hybrid charges from PV on the DC side (see pv_dc below), so the AC surplus maps
# back to DC through the loss reciprocal. Clamp by battery_to_max (remaining charge
# headroom), not battery_to_min, otherwise a near-full battery is asked to absorb
# more than it can hold and the surplus is mis-accounted instead of clipped.
battery_draw = max(-reduce_by * inverter_loss_recp, -battery_to_max, -charge_rate_now_curve_dc_step)
else:
battery_draw = max(-reduce_by * inverter_loss, -battery_to_min, -charge_rate_now_curve_step)
# Non-hybrid charges from the grid (AC), so the DC charge is the AC surplus * loss.
battery_draw = max(-reduce_by * inverter_loss, -battery_to_max, -charge_rate_now_curve_step)
else:
battery_draw = 0
else:
battery_draw = battery_draw - reduce_by
# reduce_by is an AC over-export figure but battery_draw is DC and exports through
# the inverter, so scale by the loss reciprocal to remove the right amount of grid
# export. Subtracting the raw AC figure under-reduces the battery and leaves a small
# residual that gets clipped off the solar later. Clamp at zero so we never flip to
# charging here (that case is handled by the inverter_can_charge_during_export branch).
battery_draw = max(battery_draw - reduce_by * inverter_loss_recp, 0)

if inverter_hybrid and battery_draw < 0:
pv_dc = min(abs(battery_draw), pv_now)
Expand All @@ -853,7 +869,14 @@ def run_prediction(self, charge_limit, charge_window, export_window, export_limi
* battery_rate_max_scaling
)
charge_rate_now_curve_dc_step = charge_rate_now_curve_dc * step
battery_draw = max(-reduce_by * inverter_loss, -battery_to_min, -charge_rate_now_curve_dc_step)
# reduce_by here is in the same DC-equivalent throughput units as total_inverted
# (get_total_inverted counts the battery and the PV diverted to DC 1:1), so the
# battery must charge by reduce_by directly to bring total_inverted onto the
# inverter limit - no inverter_loss factor. Multiplying by inverter_loss under-
# charges and leaves PV to be clipped that the battery could have absorbed. Clamp
# by battery_to_max (remaining charge headroom) so a near-full battery is not
# asked to absorb more than it can hold.
battery_draw = max(-reduce_by, -battery_to_max, -charge_rate_now_curve_dc_step)
else:
battery_draw = battery_draw - reduce_by

Expand Down
120 changes: 118 additions & 2 deletions apps/predbat/tests/test_model.py
Original file line number Diff line number Diff line change
Expand Up @@ -409,6 +409,118 @@ def run_model_tests(my_predbat):
failed |= simple_scenario("load_discharge_reserve", my_predbat, 1, 0, assert_final_metric=import_rate * 15, assert_final_soc=1, battery_soc=10.0, with_battery=True, reserve=1.0)
failed |= simple_scenario("load_discharge_reserve2", my_predbat, 1, 0, assert_final_metric=import_rate * 20, assert_final_soc=2, battery_soc=10.0, with_battery=True, reserve=2.0, battery_loss=0.5)
failed |= simple_scenario("load_discharge_loss", my_predbat, 1, 0, assert_final_metric=import_rate * 19, assert_final_soc=0, battery_soc=10.0, with_battery=True, battery_loss=0.5)
# Forced export with PV on a lossy hybrid inverter. The battery exports through the inverter (DC->AC) so
# when battery + solar would exceed the export limit the battery discharge must be scaled back by the loss
# reciprocal to bring grid export down to the limit. Otherwise a small residual is left above the limit and
# gets clipped off the solar. Regression test: with the scale-back correct, no solar should be clipped.
# battery_draw(DC) = (export_limit - pv_ac) / inverter_loss = (3 - 2*0.8) / 0.8 = 1.75 kW, over 24h = 42 kWh.
failed |= simple_scenario(
"export_pv_clip_loss",
my_predbat,
0,
2,
assert_final_metric=-export_rate * 24 * 3,
assert_final_soc=100 - 42,
battery_soc=100.0,
with_battery=True,
hybrid=True,
inverter_loss=0.8,
export_limit=3.0,
inverter_limit=10.0,
battery_rate_max_charge=5.0,
discharge=0,
assert_clipped=0,
)
# Forced export with PV so large that even stopping the battery leaves the solar over the export limit. With
# inverter_can_charge_during_export the battery should charge from the surplus PV (DC side) to keep grid export
# at the limit, rather than clipping the solar. Regression test for the AC/DC unit mismatch in that charge branch.
# remaining_ac = pv_ac - export_limit = 2*0.8 - 1 = 0.6; hybrid DC charge = 0.6 / 0.8 = 0.75 kW, over 24h = 18 kWh.
failed |= simple_scenario(
"export_pv_charge_clip_loss",
my_predbat,
0,
2,
assert_final_metric=-export_rate * 24,
assert_final_soc=40 + 18,
battery_soc=40.0,
with_battery=True,
hybrid=True,
inverter_loss=0.8,
export_limit=1.0,
inverter_limit=10.0,
battery_rate_max_charge=1.0,
discharge=0,
inverter_can_charge_during_export=True,
assert_clipped=0,
)
# Band case for the scale-back vs charge decision. The AC over-export (1.5kW) is larger than the battery's
# AC contribution (battery_draw 2kW DC * inverter_loss 0.5 = 1kW) but smaller than the raw DC discharge (2kW).
# The branch pivot must use the AC contribution: even after stopping the battery the 1kW AC PV is still over
# the 0.5kW export limit, so the battery should charge to absorb the 0.5kW surplus (0.25kW DC, 6kWh over 24h)
# instead of clipping it. Comparing against the raw DC value sends this to the scale-back path which just
# stops the battery and clips the solar.
failed |= simple_scenario(
"export_pv_charge_band_loss",
my_predbat,
0,
1,
assert_final_metric=-export_rate * 24 * 0.5,
assert_final_soc=50 + 0.25 * 24,
battery_soc=50.0,
with_battery=True,
inverter_loss=0.5,
export_limit=0.5,
inverter_limit=10.0,
battery_rate_max_charge=2.0,
discharge=0,
inverter_can_charge_during_export=True,
assert_clipped=0,
)
# Full battery during a high-PV forced export. PV alone (2kW) exceeds the 0.5kW export limit so the charge
# path is entered, but the battery is already at 100% so it has no headroom to absorb anything. The charge
# must be clamped by battery_to_max (0 here) so all 1.5kW AC surplus is clipped. Clamping by battery_to_min
# instead would let the model "charge" a full battery and under-report the clipping (clip 12 instead of 36).
failed |= simple_scenario(
"export_pv_charge_full_battery",
my_predbat,
0,
2,
assert_final_metric=-export_rate * 24 * 0.5,
assert_final_soc=100,
battery_soc=100.0,
with_battery=True,
export_limit=0.5,
inverter_limit=10.0,
battery_rate_max_charge=1.0,
discharge=0,
inverter_can_charge_during_export=True,
assert_clipped=24 * 1.5,
)
# Hybrid forced export where PV (4kW DC) exceeds the inverter limit (2kW) but the grid export limit is not
# binding, so the inverter-limit charge branch absorbs the surplus PV into the battery. total_inverted counts
# the battery and the DC-diverted PV 1:1, so the battery must charge by reduce_by = pv - inverter_limit = 2kW
# (not reduce_by * inverter_loss). Charging the full 2kW DC keeps total_inverted exactly on the 2kW limit with
# no clipping; charging only 1.6kW (the under-charge bug) leaves total_inverted at 2.4kW and clips 0.4kW of PV.
failed |= simple_scenario(
"export_pv_inverter_limit_charge",
my_predbat,
0,
4,
assert_final_metric=-export_rate * 1.6 * 24,
assert_final_soc=100 + 2.0 * 24,
battery_soc=100.0,
battery_size=200.0,
with_battery=True,
hybrid=True,
inverter_loss=0.8,
export_limit=100.0,
inverter_limit=2.0,
battery_rate_max_charge=1.0,
battery_rate_max_charge_dc=10.0,
discharge=0,
inverter_can_charge_during_export=True,
assert_clipped=0,
)
failed |= simple_scenario("load_pv", my_predbat, 1, 1, assert_final_metric=0, assert_final_soc=0, with_battery=False)
failed |= simple_scenario("pv_only", my_predbat, 0, 1, assert_final_metric=-export_rate * 24, assert_final_soc=0, with_battery=False)
failed |= simple_scenario("pv10_only", my_predbat, 0, 1, assert_final_metric=-export_rate * 24, assert_final_soc=0, with_battery=False, pv10=True)
Expand Down Expand Up @@ -1147,14 +1259,18 @@ def run_model_tests(my_predbat):
0,
2,
assert_final_metric=-export_rate * 24 * 0.5,
assert_final_soc=50 + 1.0 * 24 * 0.5,
# 1.5kW AC PV surplus (2kW - 0.5kW export limit). AC-coupled charging stores AC * inverter_loss as DC,
# so absorbing all 1.5kW only needs 1.5 * 0.5 = 0.75kW DC, which is within the 1kW charge rate. The
# battery therefore soaks up all the surplus and nothing is clipped (was previously under-charging at
# 0.5kW DC and clipping the rest due to an AC/DC unit mismatch in the export-limit charge branch).
assert_final_soc=50 + 0.75 * 24,
with_battery=True,
discharge=0,
battery_soc=50,
export_limit=0.5,
inverter_limit=2.0,
inverter_loss=0.5,
assert_clipped=24 * 0.5,
assert_clipped=0,
)
failed |= simple_scenario(
"battery_discharge_export_limit_ac_pv5",
Expand Down