153 changes: 153 additions & 0 deletions content/runbooks/node/NodeDiskIOQueueHigh.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,153 @@
---
title: Node Disk IO Queue High
weight: 20
---

# NodeDiskIOQueueHigh

## Meaning

The average disk I/O queue length (`aqu-sq`, equivalent to the iostat `aqu-sz`
value, or in Prometheus `rate(node_disk_io_time_weighted_seconds_total[1m])`)
on a block device has been above the warning threshold (typically `10`) for a
sustained period (e.g. 30 minutes). A persistently long request queue means
the kernel is issuing I/O faster than the device can service it.

<details>
<summary>Full context</summary>

`aqu-sq` is the time-weighted average number of I/O requests that were issued
to the device but have not yet completed (in-flight + queued). For most
SATA/SAS disks the hardware queue depth is 32; NVMe devices support up to
1024 per queue. A sustained value of `10` or more on a SATA/SAS disk
typically means the device is approaching saturation and request latency
(`await` / `r_await` / `w_await`) is climbing.

The Prometheus equivalent of `aqu-sq` from `node_exporter` is:

```
rate(node_disk_io_time_weighted_seconds_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
```

> NOTE: The blank lines above and below the text inside this `<details>` tag are required to use markdown inside of html tags.

</details>

## Impact

Any process that issues I/O against the affected device experiences higher
latency. Common consequences:

- Slow pod start-up (image pull, volume mount, container fs writes).
- kubelet / container runtime falling behind on writes (logs, cadvisor,
checkpoints) and possibly being marked `NotReady` if PLEG times out.
- etcd `fsync` / WAL latency spikes if etcd lives on this disk – which can
trigger leader elections and control-plane unavailability.
- Application-level timeouts for any workload doing synchronous writes
(databases, message brokers, log shippers).

If the queue keeps growing, requests will eventually time out at the block
layer (`blk_update_request: I/O error`) and filesystems may remount
read-only.

## Diagnosis

Replace `<INSTANCE>` and `<DEVICE>` with the values from the alert labels.

1. Confirm the symptom and identify the device on the affected node:

```
iostat -xz 2 5
```

Look for `aqu-sz` (or `aqu-sq`) above the threshold combined with high
`%util` (>90%) and rising `r_await` / `w_await`.

2. Find the heaviest writers/readers:

```
sudo iotop -oPa
sudo pidstat -d 2 5
```

3. Check whether the load comes from kernel writeback or a specific
process. Inspect dirty memory:

```
grep -E 'Dirty|Writeback' /proc/meminfo
```

4. From Prometheus, correlate the typical saturation signals over the
alert window:

```
# Queue length (this alert)
rate(node_disk_io_time_weighted_seconds_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])

# Utilization (% of time the device was busy)
rate(node_disk_io_time_seconds_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])

# Average request latency (seconds per op)
rate(node_disk_read_time_seconds_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
/ rate(node_disk_reads_completed_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
rate(node_disk_write_time_seconds_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
/ rate(node_disk_writes_completed_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])

# IOPS / throughput
rate(node_disk_reads_completed_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
rate(node_disk_writes_completed_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
rate(node_disk_read_bytes_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
rate(node_disk_written_bytes_total{device="<DEVICE>",instance="<INSTANCE>"}[1m])
```

5. Map the device to the Kubernetes workload:

```
lsblk -f
findmnt /var/lib/kubelet
findmnt /var/lib/etcd
findmnt /var/lib/containerd
crictl ps -a
```

Identify whether the device hosts `/var/lib/etcd`, kubelet pod volumes,
container image storage, or a PV. Then drain / reschedule the noisy
workload if appropriate.

6. Check the underlying hardware / virtualization layer. Long queues
without a corresponding increase in IOPS often indicate degraded media
(failing SSD, RAID rebuild, noisy neighbour on a shared LUN):

```
sudo smartctl -a /dev/<DEVICE>
sudo dmesg -T | grep -iE '<DEVICE>|ata|nvme|i/o error'
```

## Mitigation

Pick the action(s) appropriate for what diagnosis showed:

- **Noisy pod** – `kubectl cordon` the node and `kubectl drain` (or delete)
the offending pod so it is rescheduled elsewhere; lower its I/O via
`requests`/`limits` or cgroup tuning.
- **Backup / batch job** – throttle or reschedule it to off-peak hours
(e.g. via `ionice -c 3` or job-level rate limiting).
- **etcd on shared disk** – move etcd's data directory to a dedicated fast
disk; co-locating etcd with general workloads on a saturated spindle is
unsupported.
- **Failing device** – replace the disk; if it is part of a RAID array let
the array rebuild during a quiet window.
- **Tuning** – consider switching the I/O scheduler
(`/sys/block/<DEVICE>/queue/scheduler`) to `mq-deadline` (or `none` for
NVMe), increasing `nr_requests`, or enabling write caching if disabled.
- **Capacity** – if the workload legitimately needs more IOPS than the
device can provide, scale horizontally or migrate to faster storage
(NVMe / SSD / higher-tier cloud volume).

After mitigation, verify the queue length returns below the threshold:

```
rate(node_disk_io_time_weighted_seconds_total{device="<DEVICE>",instance="<INSTANCE>"}[1m]) < 10
```

[1]: https://github.github.com/gfm/#html-block