29 changes: 13 additions & 16 deletions examples/zont_prom_exporter/zont_prom_exporter.py
Original file line number Diff line number Diff line change
Expand Up @@ -4,8 +4,7 @@
import logging
from flask import Flask
from apscheduler.schedulers.background import BackgroundScheduler
from prometheus_client import make_wsgi_app, Gauge
from werkzeug.middleware.dispatcher import DispatcherMiddleware
from prometheus_client import generate_latest, Gauge, CONTENT_TYPE_LATEST
from zont_api import ZontAPI, ZontAPIException

APP_NAME = "zont_prom_exporter"
Expand All @@ -26,8 +25,6 @@

app = Flask(APP_NAME)

app.wsgi_app = DispatcherMiddleware(app.wsgi_app, {"/metrics": make_wsgi_app()})

# напряжение питания
# input voltage
VOLTAGE = Gauge("zont_input_voltage", "Input voltage", ["device_id", "sensor_id"])
Expand Down Expand Up @@ -84,16 +81,10 @@
"zont_boiler_rml", "Burner modulation level", ["device_id", "sensor_id"]
)

# авария котла
# boiler failure status
# авария котла - код последней ошибки
# boiler malfunction - latest error code
BOILER_OTA_FAILED = Gauge(
"zont_boiler_failed", "Boiler failure status", ["device_id", "sensor_id"]
)

# последний код ошибки
# boiler last error code
BOILER_OTA_ERROR = Gauge(
"zont_boiler_error", "Latest error code", ["device_id", "sensor_id"]
"zont_boiler_failed", "Boiler failure - latest error code", ["device_id", "sensor_id"]
)


Expand Down Expand Up @@ -203,12 +194,13 @@ def update_metrics() -> bool:
BOILER_OTA_RML.labels(zdevice.id, adapter_id).set(z3k_ot.get("rml"))

status = z3k_ot.get("s", [])
# TODO: should we keep these metrics permanently instead of setting on error only?
# TODO: should we keep this metric permanently instead of setting it on error only?
if "f" in status:
boiler_error = z3k_ot.get("ff", {}).get("c", -1)
logger.info("boiler error detected: E%02d", boiler_error)
BOILER_OTA_FAILED.labels(zdevice.id, adapter_id).set(1)
BOILER_OTA_ERROR.labels(zdevice.id, adapter_id).set(boiler_error)
BOILER_OTA_FAILED.labels(zdevice.id, adapter_id).set(boiler_error)
else:
BOILER_OTA_FAILED.remove(zdevice.id, adapter_id)

logger.info("%s/%s (%s) updated", zdevice.id, adapter_id, adapter_name)
except Exception as e:
Expand Down Expand Up @@ -301,5 +293,10 @@ def default():
return "Try /metrics!\n"


@app.route("/metrics")
def metrics():
return generate_latest(), 200, {'Content-Type': CONTENT_TYPE_LATEST}


if __name__ == "__main__":
main()