Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathmodel_dict.json
More file actions
197 lines (196 loc) · 64.7 KB
/
model_dict.json
File metadata and controls
197 lines (196 loc) · 64.7 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
{"feeders":[
{"name":"ieee13nodeckt",
"mRID":"_49AD8E07-3BF9-A4E2-CB8F-C3722F837B62",
"substation":"ieee13nodeckt_Substation",
"substationID":"_6C62C905-6FC7-653D-9F1E-1340F974A587",
"subregion":"test",
"subregionID":"_ABEB635F-729D-24BF-B8A4-E2EF268D8B9E",
"region":"ieee",
"regionID":"_B7C51700-3361-F2C0-67C5-B867AF818009",
"synchronousmachines":[
],
"capacitors":[
{"name":"cap1","mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","CN1":"675","phases":"ABC","kvar_A":200.0,"kvar_B":200.0,"kvar_C":200.0,"nominalVoltage":4160.0,"nomU":4160.0,"phaseConnection":"Y","grounded":true,"enabled":false,"mode":null,"targetValue":0.0,"targetDeadband":0.0,"aVRDelay":0.0,"monitoredName":null,"monitoredClass":null,"monitoredBus":null,"monitoredPhase":null},
{"name":"cap2","mRID":"_F151E337-356D-D7AB-9215-8BCBDFEC5315","CN1":"611","phases":"C","kvar_A":0.0,"kvar_B":0.0,"kvar_C":100.0,"nominalVoltage":4160.0,"nomU":2400.0,"phaseConnection":"Y","grounded":true,"enabled":false,"mode":null,"targetValue":0.0,"targetDeadband":0.0,"aVRDelay":0.0,"monitoredName":null,"monitoredClass":null,"monitoredBus":null,"monitoredPhase":null}
],
"regulators":[
{"bankName":"Reg","size":"3","bankPhases":"ABC","tankName":["reg1","reg2","reg3"],"endNumber":[2,2,2],"endPhase":["A","B","C"],"rtcName":["reg1","reg2","reg3"],"mRID":["_0C9004C7-026D-FEA2-A31E-EF5D50884C05","_C5C2E4D0-2694-0FBF-5822-8BA77A0F39C4","_19B65BE9-D229-4FF6-0972-BCDDA234C453"],"monitoredPhase":["A","B","C"],"TapChanger.tculControlMode":["volt","volt","volt"],"highStep":[32,32,32],"lowStep":[0,0,0],"neutralStep":[16,16,16],"normalStep":[16,16,16],"TapChanger.controlEnabled":[true,true,true],"lineDropCompensation":[true,true,true],"ltcFlag":[true,true,true],"RegulatingControl.enabled":[true,true,true],"RegulatingControl.discrete":[true,true,true],"RegulatingControl.mode":["voltage","voltage","voltage"],"step":[1.0625,1.0500,1.0688],"targetValue":[122.0000,122.0000,122.0000],"targetDeadband":[2.0000,2.0000,2.0000],"limitVoltage":[0.0000,0.0000,0.0000],"stepVoltageIncrement":[0.6250,0.6250,0.6250],"neutralU":[2400.0000,2400.0000,2400.0000],"initialDelay":[15.0000,15.0000,15.0000],"subsequentDelay":[2.0000,2.0000,2.0000],"lineDropR":[3.0000,3.0000,3.0000],"lineDropX":[9.0000,9.0000,9.0000],"reverseLineDropR":[0.0000,0.0000,0.0000],"reverseLineDropX":[0.0000,0.0000,0.0000],"ctRating":[700.0000,700.0000,700.0000],"ctRatio":[3500.0000,3500.0000,3500.0000],"ptRatio":[20.0000,20.0000,20.0000]}
],
"solarpanels":[
{"name":"house_PVPanels","mRID":"_0A7C655F-AC2B-FFB3-5FE7-38A6659343ED","CN1":"house","phases":"BS","ratedS":5000.0,"ratedU":208.0,"p":4000.000,"q":0.000,"maxIFault":1.111},
{"name":"school_PVPanels","mRID":"_C65F8509-4A7E-5F6E-51F0-C6D0003927BA","CN1":"634","phases":"ABC","ratedS":300000.0,"ratedU":480.0,"p":240000.000,"q":0.000,"maxIFault":1.111}
],
"batteries":[
{"name":"house_Cells","mRID":"_EF67CCD1-5358-6BB1-83BB-720FFDB36FE8","CN1":"house","phases":"BS","ratedS":5000.0,"ratedU":208.0,"p":-5000.0,"q":0.0,"ratedE":13500.0,"storedE":5000.0,"batteryState":"Charging","maxIFault":1.111},
{"name":"school_Cells","mRID":"_4CCE8235-4B6B-175E-5469-20E5771BED8C","CN1":"634","phases":"ABC","ratedS":100000.0,"ratedU":480.0,"p":-100000.0,"q":0.0,"ratedE":200000.0,"storedE":100000.0,"batteryState":"Charging","maxIFault":1.111}
],
"switches":[
{"name":"671692","mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","CN1":"671","CN2":"692","phases":"ABC","ratedCurrent":400.0,"breakingCapacity":400.0,"normalOpen":false}
],
"fuses":[
],
"sectionalisers":[
],
"breakers":[
],
"reclosers":[
],
"disconnectors":[
],
"measurements":[
{"name":"PowerTransformer_sub3_Power","mRID":"_006fbf44-f7da-4d97-867b-a4ce618a6648","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_BC2A1994-84C3-96A4-5584-80D9E43BEDF8","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650","SimObject":"xf_sub3"},
{"name":"LinearShuntCompensator_cap1","mRID":"_00bc5440-8cca-4fa7-8c96-5b42701ab838","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"Pos","phases":"B","MeasurementClass":"Discrete","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"ACLineSegment_632670_Power","mRID":"_0546c841-5876-4cec-afa8-e4820b2b7296","ConductingEquipment_mRID":"_F13F902F-BFAE-D646-161E-5323CD2312AE","Terminal_mRID":"_BAA0C183-1033-660D-4EC0-5992BA5477D8","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632670","ConnectivityNode":"632","SimObject":"line_632670"},
{"name":"ACLineSegment_645646_Voltage","mRID":"_069a6d0c-5703-44ec-807e-7045acc75ac3","ConductingEquipment_mRID":"_11963514-B483-7824-3718-5A9E8503F44F","Terminal_mRID":"_1A9D84D1-D9C5-4584-AC61-5FA75075083B","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"645646","ConnectivityNode":"646","SimObject":"line_645646"},
{"name":"PowerTransformer_sub3_Power","mRID":"_08a61a38-bfc6-4af5-b187-a538da8b8548","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_46244161-395C-56B9-7FC4-7D9D391382FA","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"sourcebus","SimObject":"xf_sub3"},
{"name":"EnergyConsumer_645","mRID":"_08dcab77-b838-4dfe-91f0-8077cb8a2373","ConductingEquipment_mRID":"_79D88B3E-5A6F-66F9-062E-6505CC96C06E","Terminal_mRID":"_50C034E5-2B9F-F0D0-F094-79ECEDF910E9","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"645","ConnectivityNode":"645","SimObject":"ld_645"},
{"name":"EnergyConsumer_671","mRID":"_0b45b9b3-44a5-427d-9c1e-be9b08ebbd91","ConductingEquipment_mRID":"_FB4F861B-DDD2-0A7B-0DB1-5AAB29220EB7","Terminal_mRID":"_23C5A020-32BA-E8DD-22D7-2F25B744112A","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"671","ConnectivityNode":"671","SimObject":"ld_671"},
{"name":"PowerElectronicsConnection_BatteryUnit_school_Cells","mRID":"_0d4e79fd-a987-4334-923c-1e0c5eda4e12","ConductingEquipment_mRID":"_F6A63E5A-0EFE-50CC-8916-4693D48DA126","Terminal_mRID":"_BB4D4CEE-6D68-CDC2-8C28-0DA99AC636FD","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"LoadBreakSwitch_671692_Voltage","mRID":"_0e2c3b80-00e6-4ece-8feb-915a83441256","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_C13BBD9B-A803-8257-C928-E3D48A6E55F3","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"692","SimObject":"swt_671692"},
{"name":"RatioTapChanger_Reg","mRID":"_0f2fb186-5c57-4ef4-8ef0-65341a88cf7e","ConductingEquipment_mRID":"_B90AA9DE-1D07-5734-517D-306DE352051E","Terminal_mRID":"_87242055-5761-3B76-6AAC-48A01B03E2A2","measurementType":"Pos","phases":"A","MeasurementClass":"Discrete","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"Reg","ConnectivityNode":"rg60","SimObject":"reg_Reg"},
{"name":"ACLineSegment_684652_Power","mRID":"_104a2576-958a-4176-9fdf-e65d5f5891dd","ConductingEquipment_mRID":"_8BCCE404-119B-BEF3-1A60-F5D6D83C2794","Terminal_mRID":"_60BB8EAF-3A57-A999-ECAC-C403C383949C","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"684652","ConnectivityNode":"684","SimObject":"line_684652"},
{"name":"PowerTransformer_xfm1_Power","mRID":"_107dda12-1364-4962-bee5-ff2e712b0b82","ConductingEquipment_mRID":"_2111F8DC-68B1-02F6-70C9-A21873CBE9BD","Terminal_mRID":"_1D8A7E4F-BBB3-DA09-E79C-50DE39B839DE","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"xfm1","ConnectivityNode":"634","SimObject":"xf_xfm1"},
{"name":"LinearShuntCompensator_cap1","mRID":"_11f6f955-4dff-49c0-86b4-d2ed1f1fc533","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"LinearShuntCompensator_cap2","mRID":"_12e0c8f5-e35c-475f-bce3-3585c8e5d397","ConductingEquipment_mRID":"_F151E337-356D-D7AB-9215-8BCBDFEC5315","Terminal_mRID":"_491844AA-FE3B-DD6C-5D8B-8DC07E134497","measurementType":"Pos","phases":"C","MeasurementClass":"Discrete","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap2","ConnectivityNode":"611","SimObject":"cap_cap2"},
{"name":"LinearShuntCompensator_cap1","mRID":"_138f9db1-f55e-4a93-a640-4c5516a55898","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"ACLineSegment_632645_Voltage","mRID":"_174ca9e5-c1cb-4325-9325-96ba2610bcbd","ConductingEquipment_mRID":"_A9D13042-AE3D-2811-2088-0D7B82B2283D","Terminal_mRID":"_19A90B16-DB7A-CADF-B79C-CF75A250E05E","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632645","ConnectivityNode":"645","SimObject":"line_632645"},
{"name":"ACLineSegment_632645_Voltage","mRID":"_177af40c-452a-4854-b331-74f6f8b96633","ConductingEquipment_mRID":"_A9D13042-AE3D-2811-2088-0D7B82B2283D","Terminal_mRID":"_19A90B16-DB7A-CADF-B79C-CF75A250E05E","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632645","ConnectivityNode":"645","SimObject":"line_632645"},
{"name":"EnergyConsumer_670c","mRID":"_180f37b0-c303-4e8d-acb1-34dbebcb9009","ConductingEquipment_mRID":"_C4C00E49-80EB-6E81-1ED9-5669CAA5A6E7","Terminal_mRID":"_3C883D0C-570C-6B6F-6B9C-2B846B698A80","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"670c","ConnectivityNode":"670","SimObject":"ld_670c"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_199f6395-3f5e-4b58-95db-50c2e9068b36","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_79C906DF-EDFB-D213-BF48-AFBD0897204A","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650z","SimObject":"xf_sub3"},
{"name":"PowerTransformer_sub3_Power","mRID":"_1b3d0458-c3fe-4cdc-87ce-b35fd1cc8d49","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_46244161-395C-56B9-7FC4-7D9D391382FA","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"sourcebus","SimObject":"xf_sub3"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_1c2f3167-26f1-43eb-a36c-79e027f74813","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_BC2A1994-84C3-96A4-5584-80D9E43BEDF8","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650","SimObject":"xf_sub3"},
{"name":"PowerTransformer_sub3_Power","mRID":"_1c825efe-93bb-4952-9a5f-316bf2ae7b0c","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_46244161-395C-56B9-7FC4-7D9D391382FA","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"sourcebus","SimObject":"xf_sub3"},
{"name":"ACLineSegment_632633_Voltage","mRID":"_1cf8d97f-1ebd-49a1-887f-d291082b4a6f","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_8831C86F-C78A-6825-C64E-2A6760C1DF0C","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"632","SimObject":"line_632633"},
{"name":"PowerTransformer_xfm1_Power","mRID":"_1d73d38d-8e27-4dc7-a8ec-1fbaffc0f5c5","ConductingEquipment_mRID":"_2111F8DC-68B1-02F6-70C9-A21873CBE9BD","Terminal_mRID":"_C142E11F-76EC-DFFF-C5BA-63CDC4CB7DF1","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"xfm1","ConnectivityNode":"633","SimObject":"xf_xfm1"},
{"name":"PowerElectronicsConnection_BatteryUnit_house_Cells","mRID":"_1f07815a-8d3a-48c7-aec4-c61111f324bf","ConductingEquipment_mRID":"_38443839-9D16-E6EC-1D5F-396B5BD2C325","Terminal_mRID":"_D29F6794-BB3C-0ABB-5F7E-595C78075CB5","measurementType":"VA","phases":"s1","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"PowerElectronicsConnection_BatteryUnit_school_Cells","mRID":"_2007f42e-c1b4-4637-8ed4-eaf685df3ac4","ConductingEquipment_mRID":"_F6A63E5A-0EFE-50CC-8916-4693D48DA126","Terminal_mRID":"_BB4D4CEE-6D68-CDC2-8C28-0DA99AC636FD","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"ACLineSegment_684652_Voltage","mRID":"_2405c3d7-2bf2-4740-9a2a-6f6814e667be","ConductingEquipment_mRID":"_8BCCE404-119B-BEF3-1A60-F5D6D83C2794","Terminal_mRID":"_E88EA6FF-357D-9B26-4F1D-AA3D590B9BC4","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"684652","ConnectivityNode":"652","SimObject":"line_684652"},
{"name":"EnergyConsumer_671","mRID":"_27e0f030-8d2e-4732-ae54-a0cb343325e2","ConductingEquipment_mRID":"_FB4F861B-DDD2-0A7B-0DB1-5AAB29220EB7","Terminal_mRID":"_23C5A020-32BA-E8DD-22D7-2F25B744112A","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"671","ConnectivityNode":"671","SimObject":"ld_671"},
{"name":"RatioTapChanger_Reg","mRID":"_28ad392e-ab47-4c83-81aa-ab537ef4ec8a","ConductingEquipment_mRID":"_B90AA9DE-1D07-5734-517D-306DE352051E","Terminal_mRID":"_0B984ED9-F4C0-F478-516E-498892B0F1FD","measurementType":"Pos","phases":"B","MeasurementClass":"Discrete","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"Reg","ConnectivityNode":"rg60","SimObject":"reg_Reg"},
{"name":"LoadBreakSwitch_671692_Voltage","mRID":"_2b15426f-0362-4268-a59c-322ef0381e9c","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_01B94435-4DA6-A26B-621F-4E30A255C8AB","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"671","SimObject":"swt_671692"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_school_PVPanels","mRID":"_33286a9f-b6fe-4892-9e19-119da0d1ae0e","ConductingEquipment_mRID":"_29DDE8D1-BE90-FC2C-51B9-5ADCDF0FD949","Terminal_mRID":"_FB66D8E0-3BA9-ED52-A08D-62BDCF90EBBC","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"PowerElectronicsConnection_BatteryUnit_house_Cells","mRID":"_334d89a7-ec89-4c77-b40b-ef9222993aa2","ConductingEquipment_mRID":"_38443839-9D16-E6EC-1D5F-396B5BD2C325","Terminal_mRID":"_D29F6794-BB3C-0ABB-5F7E-595C78075CB5","measurementType":"PNV","phases":"s1","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"LinearShuntCompensator_cap1","mRID":"_345af0ad-ced4-41d9-ad1c-dca60bc045ad","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"Pos","phases":"A","MeasurementClass":"Discrete","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"ACLineSegment_632633_Power","mRID":"_373b4285-7d9e-4807-b2ba-634144ba3ad2","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_8831C86F-C78A-6825-C64E-2A6760C1DF0C","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"632","SimObject":"line_632633"},
{"name":"ACLineSegment_632633_Voltage","mRID":"_37781717-a28c-4562-a5d1-d6e39c3d19d6","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_8831C86F-C78A-6825-C64E-2A6760C1DF0C","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"632","SimObject":"line_632633"},
{"name":"EnergyConsumer_670c","mRID":"_3844cef2-d5e9-4f57-9986-0b9c22b0268c","ConductingEquipment_mRID":"_C4C00E49-80EB-6E81-1ED9-5669CAA5A6E7","Terminal_mRID":"_3C883D0C-570C-6B6F-6B9C-2B846B698A80","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"670c","ConnectivityNode":"670","SimObject":"ld_670c"},
{"name":"ACLineSegment_632645_Power","mRID":"_3bca7dce-7bf3-48f3-9aee-f3bef669bdd0","ConductingEquipment_mRID":"_A9D13042-AE3D-2811-2088-0D7B82B2283D","Terminal_mRID":"_FF967FDB-F4D6-E078-657B-4D7EEDD26C4C","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632645","ConnectivityNode":"632","SimObject":"line_632645"},
{"name":"EnergyConsumer_675a","mRID":"_3df81c75-3670-4cac-8ca6-830da75d10bf","ConductingEquipment_mRID":"_8C2142A2-F540-0D4E-4251-CFC7930B85E2","Terminal_mRID":"_EC1342D3-D285-47F0-2304-49AF5E615A8B","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"675a","ConnectivityNode":"675","SimObject":"ld_675b"},
{"name":"ACLineSegment_671680_Voltage","mRID":"_43fa184e-4c7e-471b-b75b-3aaf6c84b6e3","ConductingEquipment_mRID":"_BE32A031-ACCD-6C21-CD76-2213E2D0AF9B","Terminal_mRID":"_464E1994-04F3-DA0A-0BF3-202EB957B20C","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671680","ConnectivityNode":"680","SimObject":"line_671680"},
{"name":"ACLineSegment_670671_Power","mRID":"_486a9683-ee66-46ab-bda1-668af04b1dc3","ConductingEquipment_mRID":"_720A3440-7F90-D332-745F-9D34C4C9FB1C","Terminal_mRID":"_76590546-D896-910B-60AE-7BE2277AC63F","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"670671","ConnectivityNode":"670","SimObject":"line_670671"},
{"name":"EnergyConsumer_670b","mRID":"_4a8fba9e-b85c-43f3-a109-6ec7d8203812","ConductingEquipment_mRID":"_AA0E14B2-C38A-0F05-5F42-7C75BBF670D6","Terminal_mRID":"_E3B2FEAE-7C87-B3EB-636D-04061887D268","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"670b","ConnectivityNode":"670","SimObject":"ld_670c"},
{"name":"ACLineSegment_671680_Voltage","mRID":"_4c0fed10-ebe1-4030-ab9f-62f667723d71","ConductingEquipment_mRID":"_BE32A031-ACCD-6C21-CD76-2213E2D0AF9B","Terminal_mRID":"_464E1994-04F3-DA0A-0BF3-202EB957B20C","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671680","ConnectivityNode":"680","SimObject":"line_671680"},
{"name":"ACLineSegment_632633_Voltage","mRID":"_4c2a3855-4bbb-4bb1-a187-6bfd932c1350","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_F43ADD4B-BD8B-CE29-07EF-B018B7162B84","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"633","SimObject":"line_632633"},
{"name":"ACLineSegment_632633_Voltage","mRID":"_4c303303-12ab-46c4-aed2-5505410b6417","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_F43ADD4B-BD8B-CE29-07EF-B018B7162B84","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"633","SimObject":"line_632633"},
{"name":"EnergyConsumer_671","mRID":"_4cff5b7b-6f51-4dc1-8b98-fcf6cf4c3bac","ConductingEquipment_mRID":"_FB4F861B-DDD2-0A7B-0DB1-5AAB29220EB7","Terminal_mRID":"_23C5A020-32BA-E8DD-22D7-2F25B744112A","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"671","ConnectivityNode":"671","SimObject":"ld_671"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_house_PVPanels","mRID":"_4d2699c9-6046-4fc2-993a-0577b121ad9c","ConductingEquipment_mRID":"_0CF0B8C8-EE37-0721-6B9E-4F6B07836F6D","Terminal_mRID":"_A5795546-F6E5-8FCE-B79B-200CBC7A126E","measurementType":"VA","phases":"s1","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"ACLineSegment_650632_Voltage","mRID":"_4e7335bb-e094-4d0f-b865-ae9015ba50a2","ConductingEquipment_mRID":"_E22C1071-34BA-DD51-1497-A9C832CDA477","Terminal_mRID":"_87023691-D5B4-58F8-0A33-E41F3C29ACE6","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"650632","ConnectivityNode":"rg60","SimObject":"line_650632"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_4e90bbf4-1fed-44de-a8c5-ba55d4ef5e88","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_BC2A1994-84C3-96A4-5584-80D9E43BEDF8","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650","SimObject":"xf_sub3"},
{"name":"PowerTransformer_sub3_Power","mRID":"_5033057d-1da3-4ead-ab98-c382ca782114","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_79C906DF-EDFB-D213-BF48-AFBD0897204A","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650z","SimObject":"xf_sub3"},
{"name":"ACLineSegment_671680_Power","mRID":"_5062ce0c-0007-4eb4-9451-73997607b165","ConductingEquipment_mRID":"_BE32A031-ACCD-6C21-CD76-2213E2D0AF9B","Terminal_mRID":"_4D532C48-7939-F4D0-B39C-40F0BAB2F1C2","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671680","ConnectivityNode":"671","SimObject":"line_671680"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_514bd989-7fb5-46db-9e3f-e2da712b1bda","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_46244161-395C-56B9-7FC4-7D9D391382FA","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"sourcebus","SimObject":"xf_sub3"},
{"name":"ACLineSegment_645646_Power","mRID":"_517ce9e7-441e-48fd-8f11-cae449bc6129","ConductingEquipment_mRID":"_11963514-B483-7824-3718-5A9E8503F44F","Terminal_mRID":"_959BF94C-57AC-4A74-9930-BF54CD5B10F0","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"645646","ConnectivityNode":"645","SimObject":"line_645646"},
{"name":"EnergyConsumer_652","mRID":"_51f2ef90-9546-4f57-bddc-4b99ae74b5ad","ConductingEquipment_mRID":"_34A02184-7FF5-A14C-2BBD-7A5E7E1DA1BF","Terminal_mRID":"_06B9D570-CA47-7982-9336-48EA68D8E792","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"652","ConnectivityNode":"652","SimObject":"ld_652"},
{"name":"LinearShuntCompensator_cap2","mRID":"_5369b0d4-c7dc-4a8f-9ac3-307e847a6ada","ConductingEquipment_mRID":"_F151E337-356D-D7AB-9215-8BCBDFEC5315","Terminal_mRID":"_491844AA-FE3B-DD6C-5D8B-8DC07E134497","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap2","ConnectivityNode":"611","SimObject":"cap_cap2"},
{"name":"ACLineSegment_671680_Voltage","mRID":"_59c495e9-acdc-4351-8400-5a42cfe8abbb","ConductingEquipment_mRID":"_BE32A031-ACCD-6C21-CD76-2213E2D0AF9B","Terminal_mRID":"_464E1994-04F3-DA0A-0BF3-202EB957B20C","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671680","ConnectivityNode":"680","SimObject":"line_671680"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_school_PVPanels","mRID":"_5aa7182c-366a-4db2-b71c-923bd0a85002","ConductingEquipment_mRID":"_29DDE8D1-BE90-FC2C-51B9-5ADCDF0FD949","Terminal_mRID":"_FB66D8E0-3BA9-ED52-A08D-62BDCF90EBBC","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"EnergyConsumer_634c","mRID":"_5e196600-0ba2-4f3b-b5e2-78fc5fe20b0f","ConductingEquipment_mRID":"_17E41D5F-0911-5F7C-D1AD-8274C0FE72EE","Terminal_mRID":"_40050108-DBA1-D6A5-4265-0067A50921C2","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"634c","ConnectivityNode":"634","SimObject":"ld_634c"},
{"name":"LoadBreakSwitch_671692_Current","mRID":"_5f8d6d11-2c2b-452b-b875-fc842232325c","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_01B94435-4DA6-A26B-621F-4E30A255C8AB","measurementType":"A","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"671","SimObject":"swt_671692"},
{"name":"EnergyConsumer_670b","mRID":"_6019b6e5-2d6d-4258-9ec7-9e712ba88436","ConductingEquipment_mRID":"_AA0E14B2-C38A-0F05-5F42-7C75BBF670D6","Terminal_mRID":"_E3B2FEAE-7C87-B3EB-636D-04061887D268","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"670b","ConnectivityNode":"670","SimObject":"ld_670c"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_house_PVPanels","mRID":"_615f981f-3bc1-44a1-88f5-0e8f55f332d0","ConductingEquipment_mRID":"_0CF0B8C8-EE37-0721-6B9E-4F6B07836F6D","Terminal_mRID":"_A5795546-F6E5-8FCE-B79B-200CBC7A126E","measurementType":"VA","phases":"s2","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"EnergyConsumer_611","mRID":"_61750104-6a84-4d62-95e6-d1fbfb3254c7","ConductingEquipment_mRID":"_3747399C-BF75-C0F0-ED62-B4CBF85857EE","Terminal_mRID":"_2ECBDCF0-019A-806E-ADDA-D717DCF2BBBA","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"611","ConnectivityNode":"611","SimObject":"ld_611"},
{"name":"ACLineSegment_632670_Power","mRID":"_6309ac2e-aca9-41fb-b878-7bb83def9197","ConductingEquipment_mRID":"_F13F902F-BFAE-D646-161E-5323CD2312AE","Terminal_mRID":"_BAA0C183-1033-660D-4EC0-5992BA5477D8","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632670","ConnectivityNode":"632","SimObject":"line_632670"},
{"name":"ACLineSegment_671684_Voltage","mRID":"_634b81ac-4675-492d-9179-a5ac7805efe8","ConductingEquipment_mRID":"_6B24752A-CE2E-2529-8756-6ECA6549FB5C","Terminal_mRID":"_DCD21BF7-B8BF-0916-A401-6FB656991882","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671684","ConnectivityNode":"684","SimObject":"line_671684"},
{"name":"EnergyConsumer_634a","mRID":"_64acd6b4-55cf-435e-ad1b-38ff309d8011","ConductingEquipment_mRID":"_AB0E8DE6-5485-4B31-16D5-AD9C6270F1C3","Terminal_mRID":"_3474F339-9CA5-BA3B-8696-B6411C76BA8E","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"634a","ConnectivityNode":"634","SimObject":"ld_634c"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_school_PVPanels","mRID":"_663fdc04-87de-4e5c-9ead-3a6d0a8d20ca","ConductingEquipment_mRID":"_29DDE8D1-BE90-FC2C-51B9-5ADCDF0FD949","Terminal_mRID":"_FB66D8E0-3BA9-ED52-A08D-62BDCF90EBBC","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"LinearShuntCompensator_cap1","mRID":"_6b056718-791f-490d-8a1e-a62bb0e9a4c7","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"LinearShuntCompensator_cap1","mRID":"_6b5220c6-557b-4f1f-b2a5-4d446245667e","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_house_PVPanels","mRID":"_6c9f2129-ec39-4b5b-acd0-e0b40fab4f57","ConductingEquipment_mRID":"_0CF0B8C8-EE37-0721-6B9E-4F6B07836F6D","Terminal_mRID":"_A5795546-F6E5-8FCE-B79B-200CBC7A126E","measurementType":"PNV","phases":"s1","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"PowerTransformer_sub3_Power","mRID":"_6cf6a212-3445-435f-ad1e-dbc1aa33c46e","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_BC2A1994-84C3-96A4-5584-80D9E43BEDF8","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650","SimObject":"xf_sub3"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_6fffd1f8-b832-4727-b898-0dc7adbef24d","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_79C906DF-EDFB-D213-BF48-AFBD0897204A","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650z","SimObject":"xf_sub3"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_house_PVPanels","mRID":"_7122485b-bf94-45ae-a95e-03c7c975751e","ConductingEquipment_mRID":"_0CF0B8C8-EE37-0721-6B9E-4F6B07836F6D","Terminal_mRID":"_A5795546-F6E5-8FCE-B79B-200CBC7A126E","measurementType":"PNV","phases":"s2","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"LoadBreakSwitch_671692_Voltage","mRID":"_717c089d-7fe2-4d0e-bd73-a761ea8de48c","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_01B94435-4DA6-A26B-621F-4E30A255C8AB","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"671","SimObject":"swt_671692"},
{"name":"ACLineSegment_670671_Power","mRID":"_71e8d1c8-81f0-4ac9-a3c0-aa3900ef6035","ConductingEquipment_mRID":"_720A3440-7F90-D332-745F-9D34C4C9FB1C","Terminal_mRID":"_76590546-D896-910B-60AE-7BE2277AC63F","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"670671","ConnectivityNode":"670","SimObject":"line_670671"},
{"name":"ACLineSegment_671680_Power","mRID":"_72571015-38de-4d74-965f-d01619778cc8","ConductingEquipment_mRID":"_BE32A031-ACCD-6C21-CD76-2213E2D0AF9B","Terminal_mRID":"_4D532C48-7939-F4D0-B39C-40F0BAB2F1C2","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671680","ConnectivityNode":"671","SimObject":"line_671680"},
{"name":"EnergyConsumer_652","mRID":"_7286d86a-7e21-4c42-aa8e-713f0f377780","ConductingEquipment_mRID":"_34A02184-7FF5-A14C-2BBD-7A5E7E1DA1BF","Terminal_mRID":"_06B9D570-CA47-7982-9336-48EA68D8E792","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"652","ConnectivityNode":"652","SimObject":"ld_652"},
{"name":"EnergyConsumer_675b","mRID":"_72b5f320-63a6-4d61-9476-a82a5a456b54","ConductingEquipment_mRID":"_F3E37C78-82C9-55BB-4EBF-59E623E483DC","Terminal_mRID":"_3B01DB4D-A869-306B-17D4-5061CC20268C","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"675b","ConnectivityNode":"675","SimObject":"ld_675b"},
{"name":"PowerTransformer_xfm1_Power","mRID":"_7399b6f7-7192-4796-8237-82f42ae5c3b0","ConductingEquipment_mRID":"_2111F8DC-68B1-02F6-70C9-A21873CBE9BD","Terminal_mRID":"_C142E11F-76EC-DFFF-C5BA-63CDC4CB7DF1","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"xfm1","ConnectivityNode":"633","SimObject":"xf_xfm1"},
{"name":"ACLineSegment_632633_Power","mRID":"_784defcb-97a5-4f96-8c46-768762ca5310","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_8831C86F-C78A-6825-C64E-2A6760C1DF0C","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"632","SimObject":"line_632633"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_793cd349-19c2-4b73-8afa-b4caa2a62948","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_46244161-395C-56B9-7FC4-7D9D391382FA","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"sourcebus","SimObject":"xf_sub3"},
{"name":"ACLineSegment_645646_Power","mRID":"_795c6c6f-52d8-4a0e-b798-d226e4b91fb2","ConductingEquipment_mRID":"_11963514-B483-7824-3718-5A9E8503F44F","Terminal_mRID":"_959BF94C-57AC-4A74-9930-BF54CD5B10F0","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"645646","ConnectivityNode":"645","SimObject":"line_645646"},
{"name":"PowerTransformer_sub3_Power","mRID":"_799f6ac1-0936-4a47-88bc-d53018a03d36","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_BC2A1994-84C3-96A4-5584-80D9E43BEDF8","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650","SimObject":"xf_sub3"},
{"name":"PowerTransformer_xfm1_Power","mRID":"_79b1bde3-d06b-47e7-8536-3feb3f237d31","ConductingEquipment_mRID":"_2111F8DC-68B1-02F6-70C9-A21873CBE9BD","Terminal_mRID":"_1D8A7E4F-BBB3-DA09-E79C-50DE39B839DE","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"xfm1","ConnectivityNode":"634","SimObject":"xf_xfm1"},
{"name":"EnergyConsumer_634b","mRID":"_7a8be00f-edcd-4d47-8527-b77f90c5a304","ConductingEquipment_mRID":"_BF172376-5FB1-E0D2-F85D-5D5A868368FD","Terminal_mRID":"_B3113156-6956-71A6-BB25-104295811838","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"634b","ConnectivityNode":"634","SimObject":"ld_634c"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_7b8e2332-67fc-4d05-8b90-8425d095307a","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_BC2A1994-84C3-96A4-5584-80D9E43BEDF8","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650","SimObject":"xf_sub3"},
{"name":"ACLineSegment_632670_Voltage","mRID":"_7ed113c8-ef15-498b-bdd4-b21534972690","ConductingEquipment_mRID":"_F13F902F-BFAE-D646-161E-5323CD2312AE","Terminal_mRID":"_83F8DAE7-C10E-0937-FD78-FA374159A5A8","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632670","ConnectivityNode":"670","SimObject":"line_632670"},
{"name":"LoadBreakSwitch_671692_Voltage","mRID":"_81c4dfa7-2912-471c-acc4-9e351a53b079","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_C13BBD9B-A803-8257-C928-E3D48A6E55F3","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"692","SimObject":"swt_671692"},
{"name":"RatioTapChanger_Reg","mRID":"_82e4a93a-aa35-4c70-a836-c0fc2633afae","ConductingEquipment_mRID":"_B90AA9DE-1D07-5734-517D-306DE352051E","Terminal_mRID":"_E16576EF-D8D4-1812-5F9F-F174F10C879E","measurementType":"Pos","phases":"C","MeasurementClass":"Discrete","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"Reg","ConnectivityNode":"rg60","SimObject":"reg_Reg"},
{"name":"ACLineSegment_650632_Power","mRID":"_83b486a0-7c01-4625-85fe-720273133db6","ConductingEquipment_mRID":"_E22C1071-34BA-DD51-1497-A9C832CDA477","Terminal_mRID":"_87023691-D5B4-58F8-0A33-E41F3C29ACE6","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"650632","ConnectivityNode":"rg60","SimObject":"line_650632"},
{"name":"ACLineSegment_684611_Power","mRID":"_8478dd9d-2ab2-46d9-8be3-76138d7e52f6","ConductingEquipment_mRID":"_C1A09E10-EF8F-ACE1-6366-973AFE595D0C","Terminal_mRID":"_5C858167-70EB-01BE-6947-30F08CEB5228","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"684611","ConnectivityNode":"684","SimObject":"line_684611"},
{"name":"EnergyConsumer_692","mRID":"_8743e380-80b4-4368-9817-9982e0d5d0b9","ConductingEquipment_mRID":"_1AA4488B-CD14-191B-270D-D75391F29A5E","Terminal_mRID":"_62A263DC-D4AB-9791-89CE-1D671BF0C1E1","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"692","ConnectivityNode":"692","SimObject":"ld_692"},
{"name":"EnergyConsumer_675a","mRID":"_87ab87ff-a8ed-489a-bc29-07774fab220b","ConductingEquipment_mRID":"_8C2142A2-F540-0D4E-4251-CFC7930B85E2","Terminal_mRID":"_EC1342D3-D285-47F0-2304-49AF5E615A8B","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"675a","ConnectivityNode":"675","SimObject":"ld_675b"},
{"name":"LinearShuntCompensator_cap1","mRID":"_892f02a0-de5e-4b1e-8096-9d7865ce734a","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"EnergyConsumer_671","mRID":"_8b5fda7a-817c-4226-a433-db4ed2050fb3","ConductingEquipment_mRID":"_FB4F861B-DDD2-0A7B-0DB1-5AAB29220EB7","Terminal_mRID":"_23C5A020-32BA-E8DD-22D7-2F25B744112A","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"671","ConnectivityNode":"671","SimObject":"ld_671"},
{"name":"LinearShuntCompensator_cap1","mRID":"_8c0d29a0-6d80-40f1-9629-713b651c3e39","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"Pos","phases":"C","MeasurementClass":"Discrete","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_school_PVPanels","mRID":"_8c13918e-38c0-47a0-862a-327ce47ad19b","ConductingEquipment_mRID":"_29DDE8D1-BE90-FC2C-51B9-5ADCDF0FD949","Terminal_mRID":"_FB66D8E0-3BA9-ED52-A08D-62BDCF90EBBC","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"EnergyConsumer_645","mRID":"_8c343e92-e38d-476e-a086-2e95baabb628","ConductingEquipment_mRID":"_79D88B3E-5A6F-66F9-062E-6505CC96C06E","Terminal_mRID":"_50C034E5-2B9F-F0D0-F094-79ECEDF910E9","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"645","ConnectivityNode":"645","SimObject":"ld_645"},
{"name":"ACLineSegment_650632_Power","mRID":"_8d5b0452-c077-44f1-94e7-b1fa95de6651","ConductingEquipment_mRID":"_E22C1071-34BA-DD51-1497-A9C832CDA477","Terminal_mRID":"_87023691-D5B4-58F8-0A33-E41F3C29ACE6","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"650632","ConnectivityNode":"rg60","SimObject":"line_650632"},
{"name":"LinearShuntCompensator_cap1","mRID":"_8e59bfed-6ff6-4f83-8dec-e1ee8b038e01","ConductingEquipment_mRID":"_4DFEE765-62A8-1339-BE70-3378ACC4A3A8","Terminal_mRID":"_0A803FCC-08EB-397E-526F-5C832F9A4974","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap1","ConnectivityNode":"675","SimObject":"cap_cap1"},
{"name":"ACLineSegment_671684_Power","mRID":"_944af5e3-753a-4b0a-8914-74a582aebba4","ConductingEquipment_mRID":"_6B24752A-CE2E-2529-8756-6ECA6549FB5C","Terminal_mRID":"_1A46DDF2-4847-990A-088E-C5BD9D5441E0","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671684","ConnectivityNode":"671","SimObject":"line_671684"},
{"name":"ACLineSegment_671684_Voltage","mRID":"_945972a7-7e7c-4382-861d-571cf68bf172","ConductingEquipment_mRID":"_6B24752A-CE2E-2529-8756-6ECA6549FB5C","Terminal_mRID":"_DCD21BF7-B8BF-0916-A401-6FB656991882","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671684","ConnectivityNode":"684","SimObject":"line_671684"},
{"name":"ACLineSegment_632670_Power","mRID":"_9511bc5e-f5ad-48b3-b49e-171bd039dc8a","ConductingEquipment_mRID":"_F13F902F-BFAE-D646-161E-5323CD2312AE","Terminal_mRID":"_BAA0C183-1033-660D-4EC0-5992BA5477D8","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632670","ConnectivityNode":"632","SimObject":"line_632670"},
{"name":"LinearShuntCompensator_cap2","mRID":"_972ab740-2ebe-4da1-9b84-f820ced493b7","ConductingEquipment_mRID":"_F151E337-356D-D7AB-9215-8BCBDFEC5315","Terminal_mRID":"_491844AA-FE3B-DD6C-5D8B-8DC07E134497","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LinearShuntCompensator","ConductingEquipment_name":"cap2","ConnectivityNode":"611","SimObject":"cap_cap2"},
{"name":"ACLineSegment_650632_Voltage","mRID":"_9a312087-0d5b-4d60-86d2-69f6eeab8327","ConductingEquipment_mRID":"_E22C1071-34BA-DD51-1497-A9C832CDA477","Terminal_mRID":"_87023691-D5B4-58F8-0A33-E41F3C29ACE6","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"650632","ConnectivityNode":"rg60","SimObject":"line_650632"},
{"name":"LoadBreakSwitch_671692_Current","mRID":"_9bdc8c91-8191-4689-a882-643fd7bc58a6","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_01B94435-4DA6-A26B-621F-4E30A255C8AB","measurementType":"A","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"671","SimObject":"swt_671692"},
{"name":"ACLineSegment_632670_Voltage","mRID":"_9bf9c7a6-a0d8-4f80-9f3b-4fe74eb481eb","ConductingEquipment_mRID":"_F13F902F-BFAE-D646-161E-5323CD2312AE","Terminal_mRID":"_83F8DAE7-C10E-0937-FD78-FA374159A5A8","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632670","ConnectivityNode":"670","SimObject":"line_632670"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_school_PVPanels","mRID":"_9cd83580-ec68-405a-af22-5e9207202c0b","ConductingEquipment_mRID":"_29DDE8D1-BE90-FC2C-51B9-5ADCDF0FD949","Terminal_mRID":"_FB66D8E0-3BA9-ED52-A08D-62BDCF90EBBC","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"ACLineSegment_645646_Voltage","mRID":"_9d173130-b4c1-4d87-ae3a-0512e911de56","ConductingEquipment_mRID":"_11963514-B483-7824-3718-5A9E8503F44F","Terminal_mRID":"_1A9D84D1-D9C5-4584-AC61-5FA75075083B","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"645646","ConnectivityNode":"646","SimObject":"line_645646"},
{"name":"EnergyConsumer_house","mRID":"_9e649c83-15d4-4557-8970-09e42805c794","ConductingEquipment_mRID":"_A7CD2A0C-EA6F-6BA0-91AC-B6912C0C7DB3","Terminal_mRID":"_0C039FC2-C327-8723-A044-01094A542CF4","measurementType":"VA","phases":"s1","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"ld_house"},
{"name":"LoadBreakSwitch_671692_Current","mRID":"_9e8773cb-f8ea-46d2-ad0d-298686054596","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_01B94435-4DA6-A26B-621F-4E30A255C8AB","measurementType":"A","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"671","SimObject":"swt_671692"},
{"name":"ACLineSegment_692675_Power","mRID":"_a19d53ac-f180-4989-b37d-e15dd26733e0","ConductingEquipment_mRID":"_96849609-E4E2-CC49-C93E-F17EB4003690","Terminal_mRID":"_35F35475-079D-0556-A655-47171C414D81","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"692675","ConnectivityNode":"692","SimObject":"line_692675"},
{"name":"ACLineSegment_632633_Voltage","mRID":"_a1c96912-7cfa-466a-a063-64e843b034ab","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_8831C86F-C78A-6825-C64E-2A6760C1DF0C","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"632","SimObject":"line_632633"},
{"name":"ACLineSegment_632633_Power","mRID":"_a40f8f90-6c32-4b70-8b89-866e8e3d0732","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_8831C86F-C78A-6825-C64E-2A6760C1DF0C","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"632","SimObject":"line_632633"},
{"name":"EnergyConsumer_675b","mRID":"_a68560c0-e5f5-466b-9688-a9430c7e7d30","ConductingEquipment_mRID":"_F3E37C78-82C9-55BB-4EBF-59E623E483DC","Terminal_mRID":"_3B01DB4D-A869-306B-17D4-5061CC20268C","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"675b","ConnectivityNode":"675","SimObject":"ld_675b"},
{"name":"PowerElectronicsConnection_BatteryUnit_school_Cells","mRID":"_a794cc9e-e191-47f4-9795-d12cc254d3af","ConductingEquipment_mRID":"_F6A63E5A-0EFE-50CC-8916-4693D48DA126","Terminal_mRID":"_BB4D4CEE-6D68-CDC2-8C28-0DA99AC636FD","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"PowerElectronicsConnection_BatteryUnit_school_Cells","mRID":"_a9bd930b-7be3-43de-b1a5-a63286c57b14","ConductingEquipment_mRID":"_F6A63E5A-0EFE-50CC-8916-4693D48DA126","Terminal_mRID":"_BB4D4CEE-6D68-CDC2-8C28-0DA99AC636FD","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"EnergyConsumer_670a","mRID":"_aaf4bdd9-2a1a-48b1-8f6c-5639115bdbd4","ConductingEquipment_mRID":"_51FA0E11-1BFF-857F-F80E-BADD2D70C07D","Terminal_mRID":"_C8A7E636-64EE-0667-97AA-057F672EFEC7","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"670a","ConnectivityNode":"670","SimObject":"ld_670c"},
{"name":"ACLineSegment_632670_Voltage","mRID":"_b01fc018-5907-4d68-9d97-f997bf98d1b6","ConductingEquipment_mRID":"_F13F902F-BFAE-D646-161E-5323CD2312AE","Terminal_mRID":"_83F8DAE7-C10E-0937-FD78-FA374159A5A8","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632670","ConnectivityNode":"670","SimObject":"line_632670"},
{"name":"PowerTransformer_sub3_Power","mRID":"_b0de3394-97a3-4f0e-b4a3-b4ac43ea8d56","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_79C906DF-EDFB-D213-BF48-AFBD0897204A","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650z","SimObject":"xf_sub3"},
{"name":"LoadBreakSwitch_671692_Voltage","mRID":"_b709ee0f-ca74-4c01-8e8d-afc51a032b8f","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_C13BBD9B-A803-8257-C928-E3D48A6E55F3","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"692","SimObject":"swt_671692"},
{"name":"EnergyConsumer_675c","mRID":"_b9a6f3ae-2778-451e-9fbd-80d0ed5f62a5","ConductingEquipment_mRID":"_501949FE-02FB-AA29-784A-D388F4D3C3AE","Terminal_mRID":"_962BE6D7-AF77-7B26-9A0B-13617E3439FB","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"675c","ConnectivityNode":"675","SimObject":"ld_675b"},
{"name":"EnergyConsumer_670a","mRID":"_bea69c61-91c3-4deb-bfff-c75a31e6227a","ConductingEquipment_mRID":"_51FA0E11-1BFF-857F-F80E-BADD2D70C07D","Terminal_mRID":"_C8A7E636-64EE-0667-97AA-057F672EFEC7","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"670a","ConnectivityNode":"670","SimObject":"ld_670c"},
{"name":"ACLineSegment_670671_Power","mRID":"_bf11b4cd-5128-428f-a2f0-8e826db36dcb","ConductingEquipment_mRID":"_720A3440-7F90-D332-745F-9D34C4C9FB1C","Terminal_mRID":"_76590546-D896-910B-60AE-7BE2277AC63F","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"670671","ConnectivityNode":"670","SimObject":"line_670671"},
{"name":"EnergyConsumer_634a","mRID":"_bf617ecf-de3d-43c8-97bf-ca83646cb9d3","ConductingEquipment_mRID":"_AB0E8DE6-5485-4B31-16D5-AD9C6270F1C3","Terminal_mRID":"_3474F339-9CA5-BA3B-8696-B6411C76BA8E","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"634a","ConnectivityNode":"634","SimObject":"ld_634c"},
{"name":"EnergyConsumer_634c","mRID":"_c2721663-9ff5-406f-8cda-9a82907dbe35","ConductingEquipment_mRID":"_17E41D5F-0911-5F7C-D1AD-8274C0FE72EE","Terminal_mRID":"_40050108-DBA1-D6A5-4265-0067A50921C2","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"634c","ConnectivityNode":"634","SimObject":"ld_634c"},
{"name":"EnergyConsumer_646","mRID":"_c2ca3541-73a5-4ae3-b4a0-7992fac9b5bb","ConductingEquipment_mRID":"_44DEEFCA-B468-2C84-1D31-4E2B9C5A1290","Terminal_mRID":"_71031C1B-431F-FDDF-E49B-F31570AFCB20","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"646","ConnectivityNode":"646","SimObject":"ld_646"},
{"name":"EnergyConsumer_house","mRID":"_c384b3f8-9cf9-4504-8447-80642976e2c6","ConductingEquipment_mRID":"_A7CD2A0C-EA6F-6BA0-91AC-B6912C0C7DB3","Terminal_mRID":"_0C039FC2-C327-8723-A044-01094A542CF4","measurementType":"PNV","phases":"s2","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"ld_house"},
{"name":"EnergyConsumer_671","mRID":"_c79a6db1-66e5-4143-8d5f-32c42e445f84","ConductingEquipment_mRID":"_FB4F861B-DDD2-0A7B-0DB1-5AAB29220EB7","Terminal_mRID":"_23C5A020-32BA-E8DD-22D7-2F25B744112A","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"671","ConnectivityNode":"671","SimObject":"ld_671"},
{"name":"ACLineSegment_671684_Power","mRID":"_c952c031-346a-4909-bc9d-a78898a4056c","ConductingEquipment_mRID":"_6B24752A-CE2E-2529-8756-6ECA6549FB5C","Terminal_mRID":"_1A46DDF2-4847-990A-088E-C5BD9D5441E0","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671684","ConnectivityNode":"671","SimObject":"line_671684"},
{"name":"PowerTransformer_xfm1_Power","mRID":"_cd60c9c1-4144-425e-a42e-5c6a44df29d9","ConductingEquipment_mRID":"_2111F8DC-68B1-02F6-70C9-A21873CBE9BD","Terminal_mRID":"_1D8A7E4F-BBB3-DA09-E79C-50DE39B839DE","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"xfm1","ConnectivityNode":"634","SimObject":"xf_xfm1"},
{"name":"ACLineSegment_632633_Voltage","mRID":"_cf0a35b1-2789-4e5d-8a5d-a78d0824331f","ConductingEquipment_mRID":"_52758BAC-F3F1-B44F-D11F-C3063982684F","Terminal_mRID":"_F43ADD4B-BD8B-CE29-07EF-B018B7162B84","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632633","ConnectivityNode":"633","SimObject":"line_632633"},
{"name":"ACLineSegment_650632_Power","mRID":"_cf275661-f909-4a5f-baf2-57bc97d3ad20","ConductingEquipment_mRID":"_E22C1071-34BA-DD51-1497-A9C832CDA477","Terminal_mRID":"_87023691-D5B4-58F8-0A33-E41F3C29ACE6","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"650632","ConnectivityNode":"rg60","SimObject":"line_650632"},
{"name":"PowerElectronicsConnection_BatteryUnit_school_Cells","mRID":"_d1a745b7-15e3-4ad9-8246-160a05da0f2c","ConductingEquipment_mRID":"_F6A63E5A-0EFE-50CC-8916-4693D48DA126","Terminal_mRID":"_BB4D4CEE-6D68-CDC2-8C28-0DA99AC636FD","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"ACLineSegment_671680_Power","mRID":"_d1ef66f9-fba9-42ee-95ed-059b3d6a2e10","ConductingEquipment_mRID":"_BE32A031-ACCD-6C21-CD76-2213E2D0AF9B","Terminal_mRID":"_4D532C48-7939-F4D0-B39C-40F0BAB2F1C2","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"671680","ConnectivityNode":"671","SimObject":"line_671680"},
{"name":"PowerTransformer_xfm1_Power","mRID":"_d359871f-418d-42ec-87fe-092cf8228487","ConductingEquipment_mRID":"_2111F8DC-68B1-02F6-70C9-A21873CBE9BD","Terminal_mRID":"_C142E11F-76EC-DFFF-C5BA-63CDC4CB7DF1","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"xfm1","ConnectivityNode":"633","SimObject":"xf_xfm1"},
{"name":"EnergyConsumer_671","mRID":"_d66a7123-af6c-4ab1-9515-ce7166e1faf1","ConductingEquipment_mRID":"_FB4F861B-DDD2-0A7B-0DB1-5AAB29220EB7","Terminal_mRID":"_23C5A020-32BA-E8DD-22D7-2F25B744112A","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"671","ConnectivityNode":"671","SimObject":"ld_671"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_d6c3db00-0dd7-4982-93f0-5150e0f6f43b","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_46244161-395C-56B9-7FC4-7D9D391382FA","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"sourcebus","SimObject":"xf_sub3"},
{"name":"LoadBreakSwitch_671692_Voltage","mRID":"_d872ea39-1a75-4d36-b46a-a0b3edc008de","ConductingEquipment_mRID":"_DDE4C6BE-8646-5AFE-D6C6-1C7F5F740527","Terminal_mRID":"_01B94435-4DA6-A26B-621F-4E30A255C8AB","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"LoadBreakSwitch","ConductingEquipment_name":"671692","ConnectivityNode":"671","SimObject":"swt_671692"},
{"name":"EnergyConsumer_house","mRID":"_d95d7529-21b6-402e-a4ab-f6ee0579bdf6","ConductingEquipment_mRID":"_A7CD2A0C-EA6F-6BA0-91AC-B6912C0C7DB3","Terminal_mRID":"_0C039FC2-C327-8723-A044-01094A542CF4","measurementType":"VA","phases":"s2","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"ld_house"},
{"name":"EnergyConsumer_634b","mRID":"_dcc6c97c-ab6b-41ce-96f3-7ea4c94cc0a2","ConductingEquipment_mRID":"_BF172376-5FB1-E0D2-F85D-5D5A868368FD","Terminal_mRID":"_B3113156-6956-71A6-BB25-104295811838","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"634b","ConnectivityNode":"634","SimObject":"ld_634c"},
{"name":"EnergyConsumer_675c","mRID":"_dd8f5771-3c39-4512-9cd0-919ff4b2c08e","ConductingEquipment_mRID":"_501949FE-02FB-AA29-784A-D388F4D3C3AE","Terminal_mRID":"_962BE6D7-AF77-7B26-9A0B-13617E3439FB","measurementType":"VA","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"675c","ConnectivityNode":"675","SimObject":"ld_675b"},
{"name":"ACLineSegment_650632_Voltage","mRID":"_dea31693-f682-48f9-b3ca-dcdb330b8590","ConductingEquipment_mRID":"_E22C1071-34BA-DD51-1497-A9C832CDA477","Terminal_mRID":"_87023691-D5B4-58F8-0A33-E41F3C29ACE6","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"650632","ConnectivityNode":"rg60","SimObject":"line_650632"},
{"name":"PowerTransformer_sub3_Voltage","mRID":"_df18ed36-4e8b-48fe-a398-7055867b0b6d","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_79C906DF-EDFB-D213-BF48-AFBD0897204A","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650z","SimObject":"xf_sub3"},
{"name":"EnergyConsumer_house","mRID":"_dfc4707a-d117-4a4d-85ea-dcca114cdd71","ConductingEquipment_mRID":"_A7CD2A0C-EA6F-6BA0-91AC-B6912C0C7DB3","Terminal_mRID":"_0C039FC2-C327-8723-A044-01094A542CF4","measurementType":"PNV","phases":"s1","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"ld_house"},
{"name":"EnergyConsumer_646","mRID":"_e3eb9074-56af-472e-bab5-ff7a26e9f3e9","ConductingEquipment_mRID":"_44DEEFCA-B468-2C84-1D31-4E2B9C5A1290","Terminal_mRID":"_71031C1B-431F-FDDF-E49B-F31570AFCB20","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"646","ConnectivityNode":"646","SimObject":"ld_646"},
{"name":"ACLineSegment_692675_Power","mRID":"_e41ee24b-253e-4b20-ad1a-feddb726fe11","ConductingEquipment_mRID":"_96849609-E4E2-CC49-C93E-F17EB4003690","Terminal_mRID":"_35F35475-079D-0556-A655-47171C414D81","measurementType":"VA","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"692675","ConnectivityNode":"692","SimObject":"line_692675"},
{"name":"ACLineSegment_692675_Power","mRID":"_e7dba515-75cc-48be-8105-0b0e83c4722f","ConductingEquipment_mRID":"_96849609-E4E2-CC49-C93E-F17EB4003690","Terminal_mRID":"_35F35475-079D-0556-A655-47171C414D81","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"692675","ConnectivityNode":"692","SimObject":"line_692675"},
{"name":"EnergyConsumer_692","mRID":"_ec22f9ab-9b5d-41d9-9bf3-008fae30a9ea","ConductingEquipment_mRID":"_1AA4488B-CD14-191B-270D-D75391F29A5E","Terminal_mRID":"_62A263DC-D4AB-9791-89CE-1D671BF0C1E1","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"692","ConnectivityNode":"692","SimObject":"ld_692"},
{"name":"PowerTransformer_sub3_Power","mRID":"_ede509c5-6f82-46ba-8df4-30db594d697e","ConductingEquipment_mRID":"_3AF560EE-A3E5-EADD-BCA3-EB5668817A27","Terminal_mRID":"_79C906DF-EDFB-D213-BF48-AFBD0897204A","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerTransformer","ConductingEquipment_name":"sub3","ConnectivityNode":"650z","SimObject":"xf_sub3"},
{"name":"PowerElectronicsConnection_BatteryUnit_school_Cells","mRID":"_f4d4cdcb-fc87-40d3-8750-4ff49e7963ff","ConductingEquipment_mRID":"_F6A63E5A-0EFE-50CC-8916-4693D48DA126","Terminal_mRID":"_BB4D4CEE-6D68-CDC2-8C28-0DA99AC636FD","measurementType":"PNV","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"PowerElectronicsConnection_PhotovoltaicUnit_school_PVPanels","mRID":"_f5f4165d-031e-4e6f-84e5-11a4cf24f404","ConductingEquipment_mRID":"_29DDE8D1-BE90-FC2C-51B9-5ADCDF0FD949","Terminal_mRID":"_FB66D8E0-3BA9-ED52-A08D-62BDCF90EBBC","measurementType":"PNV","phases":"A","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"school","ConnectivityNode":"634","SimObject":"634_stmtr"},
{"name":"PowerElectronicsConnection_BatteryUnit_house_Cells","mRID":"_f7d001bc-0523-4149-bd39-313ce443ac51","ConductingEquipment_mRID":"_38443839-9D16-E6EC-1D5F-396B5BD2C325","Terminal_mRID":"_D29F6794-BB3C-0ABB-5F7E-595C78075CB5","measurementType":"PNV","phases":"s2","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"PowerElectronicsConnection_BatteryUnit_house_Cells","mRID":"_f7eade39-cea6-4c84-861d-4d8e592f6ea0","ConductingEquipment_mRID":"_38443839-9D16-E6EC-1D5F-396B5BD2C325","Terminal_mRID":"_D29F6794-BB3C-0ABB-5F7E-595C78075CB5","measurementType":"VA","phases":"s2","MeasurementClass":"Analog","ConductingEquipment_type":"PowerElectronicsConnection","ConductingEquipment_name":"house","ConnectivityNode":"house","SimObject":"house_stmtr"},
{"name":"ACLineSegment_632645_Power","mRID":"_ff3291ca-40d3-4e40-abf4-d5a091e350ad","ConductingEquipment_mRID":"_A9D13042-AE3D-2811-2088-0D7B82B2283D","Terminal_mRID":"_FF967FDB-F4D6-E078-657B-4D7EEDD26C4C","measurementType":"VA","phases":"B","MeasurementClass":"Analog","ConductingEquipment_type":"ACLineSegment","ConductingEquipment_name":"632645","ConnectivityNode":"632","SimObject":"line_632645"},
{"name":"EnergyConsumer_611","mRID":"_ffabfa14-276b-4582-a69f-eccb088499f3","ConductingEquipment_mRID":"_3747399C-BF75-C0F0-ED62-B4CBF85857EE","Terminal_mRID":"_2ECBDCF0-019A-806E-ADDA-D717DCF2BBBA","measurementType":"PNV","phases":"C","MeasurementClass":"Analog","ConductingEquipment_type":"EnergyConsumer","ConductingEquipment_name":"611","ConnectivityNode":"611","SimObject":"ld_611"}
]
}]}