Hi,

Thanks for sharing this interesting piece of work! I have a quick question about the Center Relative PE section in your paper. The formula you mentioned in your paper to calculate the PE for some given patch is:

Wrong

With this formula, I believe we can not get the following Center Relative PE you showed in your paper:

SQSFormer PE

In order to get the above representation your formula should have been like:

right

With this formula we can get the above PE values.