Description
Enhancement Request
Once v23.2-IOFreeze is released, we should update to it.
Detailed Description
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/InputRulesFiles/Rules23-1-0-to-23-2-0.md
https://github.com/NREL/EnergyPlus/blob/develop/src/Transition/OutputRulesFiles/OutputChanges23-1-0-to-23-2-0.md
Major changes
-
Fuel Type enum changes (
OtherEquipment,Exterior:FuelEquipment,ZoneHVAC:HybridUnitaryHVAC, etc.)- "DistrictHeating" to "DistrictHeatingWater"
- "Steam" to "DistrictHeatingSteam"
- V23.2.0-IOFreeze - Fuel Type enum changes (DistrictHeatingWater / DistrictHeatingSteam) #4968
- Watch status of this PR and add DistrictCooling/DistictHeatingSteam in LCC objects
-
v23.2.0-IOFreeze: Coil and Unitary systems changes #4958
-
Coil:Cooling:DX:*,Coil:Heating:DX:*,Coil:WaterHeating:*: new "Crankcase Heater Capacity Function of Temperature Curve Name" field -
Coil:Cooling:DX:TwoSpeed,Coil:Cooling:DX:VariableSpeedCoil:Heating:DX:VariableSpeed: add fields "High Speed 2017 Rated Evaporator Fan Power Per Volume Flow Rate", "High Speed 2023 Rated Evaporator Fan Power Per Volume Flow Rate", "Low Speed 2017 Rated Evaporator Fan Power Per Volume Flow Rate", and "Low Speed 2023 Rated Evaporator Fan Power Per Volume Flow Rate" -
AirLoopHVAC:UnitarySystem,AirLoopHVAC:UnitaryHeatPump :WaterToAir(not wrapped),ZoneHVAC:WaterToAirHeatPump: remove a handful of fields -
Coil:Cooling:DX:VariableSpeed,Coil:Cooling:WaterToAirHeatPump:VariableSpeedEquationFit: add fields "Maximum Cycling Rate", "Latent Capacity Time Constant", "Fan Delay Time" -
Coil:Cooling:WaterToAirHeatPump:ParameterEstimation(not wrapped),Coil:Cooling:WaterToAirHeatPump:EquationFit: add fields "Part Load Fraction Correlation Curve Name", "Maximum Cycling Rate", "Latent Capacity Time Constant", "Fan Delay Time" -
Coil:Heating:WaterToAirHeatPump:ParameterEstimation(not wrapped),Coil:Heating:WaterToAirHeatPump:EquationFit: add field "Part Load Fraction Correlation Curve Name"
-
-
HeatPump:PlantLoop:EIR:Cooling,HeatPump:PlantLoop:EIR:Heating: required field changes, and some new fields
New additions
-
ZoneEarthtube: two new fields;ZoneEarthtube:Parameters: new object -
SpaceHVAC:EquipmentConnections,SpaceHVAC:ZoneEquipmentSplitter,SpaceHVAC:ZoneEquipmentMixer: new object -
DistrictHeating:Steam: new object -
PlantEquipmentOperation:ChillerHeaterChangeover: new object
Minor stuff
-
DistrictHeatingtoDistrictHeating:Water: new object name in forward translation -
SurfaceProperty:LocalEnvironment: change "External Shading Fraction Schedule Name" to "Sunlit Fraction Schedule Name" -
HVACTemplate:Zone:WaterToAirHeatPump(not wrapped): rename "Heat Pump Time Constant" to "Latent Capacity Time Constant" and remove "Fraction of On-Cycle Power Use" -
ZoneHVAC:EvaporativeCoolerUnit(not wrapped): add field "Shut Off Relative Humidity" -
ZoneHVAC:WaterToAirHeatPump,ZoneHVAC:TerminalUnit:VariableRefrigerantFlow: add fields "Design Specification Multispeed Object Type" and "Design Specification Multispeed Object Name" -
Coil:Heating:Fuel,Coil:Heating:Gas:MultiStage,Coil:Heating:Desuperheater: rename "Parasitic Electric Load" to "On Cycle Parasitic Electric Load" and "Parasitic Fuel Load" to "Off Cycle Parasitic Fuel Load" -
Boiler:HotWater: rename "Parasitic Electric Load" to "On Cycle Parasitic Electric Load" and add "Off Cycle Parasitic Fuel Load" -
Controller:OutdoorAir: new field "Economizer Operation Staging" -
LoadProfile:Plant: new fields "Plant Loop Fluid Type", "Degree of SubCooling", "Degree of Loop SubCooling" -
EnvironmentalImpactFactors: update field names
Other
- Fix a bunch of spelling in ProposedEnergy+.idd, including exectuted, repeate, similiar, etc.
-
ConstructionProperty:InternalHeatSource: remove\note required-fieldline -
Construction:ComplexFenestrationState: fix "Absoptance" spelling in fields